Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Molecules ; 28(8)2023 Apr 20.
Article in English | MEDLINE | ID: covidwho-2293250

ABSTRACT

Disease-related biomarkers may serve as indicators of human disease. The clinical diagnosis of diseases may largely benefit from timely and accurate detection of biomarkers, which has been the subject of extensive investigations. Due to the specificity of antibody and antigen recognition, electrochemical immunosensors can accurately detect multiple disease biomarkers, including proteins, antigens, and enzymes. This review deals with the fundamentals and types of electrochemical immunosensors. The electrochemical immunosensors are developed using three different catalysts: redox couples, typical biological enzymes, and nanomimetic enzymes. This review also focuses on the applications of those immunosensors in the detection of cancer, Alzheimer's disease, novel coronavirus pneumonia and other diseases. Finally, the future trends in electrochemical immunosensors are addressed in terms of achieving lower detection limits, improving electrode modification capabilities and developing composite functional materials.


Subject(s)
Biosensing Techniques , COVID-19 , Humans , Immunoassay , Electrochemical Techniques , COVID-19/diagnosis , Biomarkers
2.
Acs Biomaterials Science & Engineering ; 9(1):458-473, 2023.
Article in English | Web of Science | ID: covidwho-2243827

ABSTRACT

Even after over 2 years of the COVID-19 pandemic, research on rapid, inexpensive, and accurate tests remains essential for controlling and avoiding the global spread of SARS-CoV-2 across the planet during a potential reappearance in future global waves or regional outbreaks. Assessment of serological responses for COVID-19 can be beneficial for population-level surveillance purposes, supporting the development of novel vaccines and evaluating the efficacy of different immunization programs. This can be especially relevant for broadly used inactivated whole virus vaccines, such as CoronaVac, which produced lower titers of neutralizing antibodies. and showed lower efficacy for specific groups such as the elderly and immunocompromised. We developed an impedimetric biosensor based on the immobilization of SARS-CoV-2 recombinant trimeric spike protein (S protein) on zinc oxide nanorod (ZnONR)-modified fluorine-doped tin oxide substrates for COVID-19 serology testing. Due to electrostatic interactions, the negatively charged S protein was immobilized via physical adsorption. The electrochemical response of the immunosensor was measured at each modification step and characterized by scanning electron microscopy and electrochemical techniques. We successfully evaluated the applicability of the modified ZnONR electrodes using serum samples from COVID-19 convalescent individuals, CoronaVac-vaccinated with or without positive results for SARS-CoV-2 infection, and pre-pandemic samples from healthy volunteers as controls. ELISA for IgG anti-SARS-CoV-2 spike protein was performed for comparison, and ELISA for IgG anti-RBDs of seasonal coronavirus (HCoVs) was used to test the specificity of immunosensor detection. No cross-reactivity with HCoVs was detected using the ZnONR immunosensor, and more interestingly, the sensor presented higher sensitivity when compared to negative ELISA results. The results demonstrate that the ZnONRs/spike-modified electrode displayed sensitive results for convalescents and vaccinated samples and shows excellent potential as a tool for the population's assessment and monitoring of seroconversion and seroprevalence.

3.
ACS Biomater Sci Eng ; 2022 Sep 01.
Article in English | MEDLINE | ID: covidwho-2016534

ABSTRACT

Even after over 2 years of the COVID-19 pandemic, research on rapid, inexpensive, and accurate tests remains essential for controlling and avoiding the global spread of SARS-CoV-2 across the planet during a potential reappearance in future global waves or regional outbreaks. Assessment of serological responses for COVID-19 can be beneficial for population-level surveillance purposes, supporting the development of novel vaccines and evaluating the efficacy of different immunization programs. This can be especially relevant for broadly used inactivated whole virus vaccines, such as CoronaVac, which produced lower titers of neutralizing antibodies. and showed lower efficacy for specific groups such as the elderly and immunocompromised. We developed an impedimetric biosensor based on the immobilization of SARS-CoV-2 recombinant trimeric spike protein (S protein) on zinc oxide nanorod (ZnONR)-modified fluorine-doped tin oxide substrates for COVID-19 serology testing. Due to electrostatic interactions, the negatively charged S protein was immobilized via physical adsorption. The electrochemical response of the immunosensor was measured at each modification step and characterized by scanning electron microscopy and electrochemical techniques. We successfully evaluated the applicability of the modified ZnONR electrodes using serum samples from COVID-19 convalescent individuals, CoronaVac-vaccinated with or without positive results for SARS-CoV-2 infection, and pre-pandemic samples from healthy volunteers as controls. ELISA for IgG anti-SARS-CoV-2 spike protein was performed for comparison, and ELISA for IgG anti-RBDs of seasonal coronavirus (HCoVs) was used to test the specificity of immunosensor detection. No cross-reactivity with HCoVs was detected using the ZnONR immunosensor, and more interestingly, the sensor presented higher sensitivity when compared to negative ELISA results. The results demonstrate that the ZnONRs/spike-modified electrode displayed sensitive results for convalescents and vaccinated samples and shows excellent potential as a tool for the population's assessment and monitoring of seroconversion and seroprevalence.

4.
25th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2021 ; : 1445-1446, 2021.
Article in English | Scopus | ID: covidwho-2012281

ABSTRACT

A portable and low-cost electrochemical immunosensor platform is developed for rapid (13 min) and accurate quantification of SARS-CoV-2 serum antibodies (10.1 ng/mL − 60 µg/mL for IgG and 1.64 ng/mL − 50 µg/mL for IgM). No obvious cross-reactivity with other interference proteins was observed. Stable performance of the immunosensor within 24-week storage at room temperature was achieved. The practical use of the immunosensor was demonstrated using real patient samples. © 2021 MicroTAS 2021 - 25th International Conference on Miniaturized Systems for Chemistry and Life Sciences. All rights reserved.

5.
Diagnostics (Basel) ; 12(8)2022 Aug 17.
Article in English | MEDLINE | ID: covidwho-1987686

ABSTRACT

After the COVID-19 pandemic started all over the world, great importance was placed on the development of sensitive and selective bioanalytical assays for the rapid detection of the highly pathogenic SARS-CoV-2 virus causing COVID-19 disease. In this present work, an impedimetric immunosensor was developed and applied for rapid, reliable, sensitive and selective detection of the SARS-CoV-2 S1 protein. To detect the SARS-CoV-2 virus, targeting of the spike S1 protein was achieved herein by using S1 protein-specific capture antibody (Cab-S1) immobilized screen-printed electrode (SPE) in combination with the electrochemical impedance spectroscopy (EIS) technique. With the impedimetric immunosensor, the detection limit for S1 protein in buffer medium was found to be 0.23 ng/mL (equal to 23.92 amol in 8 µL sample) in the linear concentration range of S1 protein from 0.5 to 10 ng/mL. In the artificial saliva medium, it was found to be 0.09 ng/mL (equals to 9.36 amol in 8 µL sample) in the linear concentration range of S1 protein between 0.1 and 1 ng/mL. The selectivity of the impedimetric immunosensor toward S1 protein was tested against influenza hemagglutinin antigen (HA) in the buffer medium as well as in artificial saliva.

6.
Talanta ; 244: 123422, 2022 Jul 01.
Article in English | MEDLINE | ID: covidwho-1763988

ABSTRACT

In this present study, an amperometric immunosensor was developed based on disposable screen-printed carbon electrode (SPCE) for specific and sensitive detection of SARS-CoV-2 S1 protein. Anti-SARS-CoV-2 S1 monoclonal antibody was firstly immobilized onto the electrode surface. Then, the sandwich complex was formed by addition of S1 protein, secondary antibody and HRP-IgG, respectively. Chronoamperometry measurements were done in the presence of TMB mediator and the detection of SARS-CoV-2 S1 protein was performed by using 10 µL sample. The limit of detection (LOD) was found to be 0.19 ng/mL (equals to 24.7 amol in 10 µL sample) in the linear range of 0.5-10 ng/mL obtained in buffer medium. The applicability of this assay was investigated in the linear range of 0.5-3 ng/mL S1 protein in artificial saliva medium with the LOD as 0.13 ng/mL (equals to 16.9 amol in 10 µL sample). The selectivity study was examined in the presence of Hemagglutinin antigen (HA) in both mediums; buffer and artificial saliva while resulting with the successful discrimination between S1 protein and HA. The one of ultimate goals of our study is to present the possible implementation of this assay to point of care (POC) analysis. Under this aim, this assay was performed in combination with a portable device that is the commercial electrochemical analyzer. Amperometric detection of S1 protein in the range of 0.5-5 ng/mL was also successfully performed in artificial saliva medium with a resulting LOD as 0.15 ng/mL (equals to 19.5 amol in 10 µL sample). In addition, a selectivity study was similarly carried out by portable device.


Subject(s)
Biosensing Techniques , COVID-19 , Antibodies, Viral , Biosensing Techniques/methods , COVID-19/diagnosis , Humans , Immunoassay/methods , SARS-CoV-2 , Saliva, Artificial
7.
Int J Mol Sci ; 23(2)2022 Jan 08.
Article in English | MEDLINE | ID: covidwho-1613827

ABSTRACT

Monitoring and tracking infection is required in order to reduce the spread of the coronavirus disease 2019 (COVID-19), induced by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). To achieve this goal, the development and deployment of quick, accurate, and sensitive diagnostic methods are necessary. The determination of the SARS-CoV-2 virus is performed by biosensing devices, which vary according to detection methods and the biomarkers which are inducing/providing an analytical signal. RNA hybridisation, antigen-antibody affinity interaction, and a variety of other biological reactions are commonly used to generate analytical signals that can be precisely detected using electrochemical, electrochemiluminescence, optical, and other methodologies and transducers. Electrochemical biosensors, in particular, correspond to the current trend of bioanalytical process acceleration and simplification. Immunosensors are based on the determination of antigen-antibody interaction, which on some occasions can be determined in a label-free mode with sufficient sensitivity.


Subject(s)
Biosensing Techniques/methods , COVID-19 Testing/methods , SARS-CoV-2/chemistry , Humans , Molecular Diagnostic Techniques , Nanostructures , SARS-CoV-2/isolation & purification , Serologic Tests
8.
Micromachines (Basel) ; 12(4)2021 Apr 02.
Article in English | MEDLINE | ID: covidwho-1167660

ABSTRACT

The coronavirus disease 2019 (COVID-19) outbreak caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was proclaimed a global pandemic in March 2020. Reducing the dissemination rate, in particular by tracking the infected people and their contacts, is the main instrument against infection spreading. Therefore, the creation and implementation of fast, reliable and responsive methods suitable for the diagnosis of COVID-19 are required. These needs can be fulfilled using affinity sensors, which differ in applied detection methods and markers that are generating analytical signals. Recently, nucleic acid hybridization, antigen-antibody interaction, and change of reactive oxygen species (ROS) level are mostly used for the generation of analytical signals, which can be accurately measured by electrochemical, optical, surface plasmon resonance, field-effect transistors, and some other methods and transducers. Electrochemical biosensors are the most consistent with the general trend towards, acceleration, and simplification of the bioanalytical process. These biosensors mostly are based on the determination of antigen-antibody interaction and are robust, sensitive, accurate, and sometimes enable label-free detection of an analyte. Along with the specification of biosensors, we also provide a brief overview of generally used testing techniques, and the description of the structure, life cycle and immune host response to SARS-CoV-2, and some deeper details of analytical signal detection principles.

SELECTION OF CITATIONS
SEARCH DETAIL